Motor Starters
List prices across all OEM brands · 579 products
Single phase starter, 2 modules, 20A
20A · 2
OEM List Price
OEM List Price
Single phase starter, 2 modules, 25A
25A · 2
OEM List Price
Manual motor starter, 0.06 kW rated power, 0.2 A rated current, 2.44 A instantaneous tripping current, 0.16-0.25 A current setting range.
0.06 · 0.2 · 0.16-0.25 · 2.44
Manual motor starter, 0.09 kW rated power, 0.3 A rated current, 3.9 A instantaneous tripping current, 0.25-0.40 A current setting range.
0.09 · 0.3 · 0.25-0.40 · 3.9
Manual motor starter, 0.12 kW rated power, 0.44 A rated current, 6.14 A instantaneous tripping current, 0.40-0.63 A current setting range.
0.12 · 0.44 · 0.40-0.63 · 6.14
Manual motor starter, 0.25 kW rated power, 0.85 A rated current, 11.5 A instantaneous tripping current, 0.63-1.00 A current setting range.
0.25 · 0.85 · 0.63-1.00 · 11.5
Manual motor starter, 0.37 kW rated power, 1.1 A rated current, 18.4 A instantaneous tripping current, 1.00-1.60 A current setting range.
0.37 · 1.1 · 1.00-1.60 · 18.4
Manual motor starter, 5.5 kW rated power, 11.5 A rated current, 180 A instantaneous tripping current, 8.00-12.00 A current setting range.
5.5 · 11.5 · 8.00-12.00 · 180
Manual motor starter, 0.75 kW rated power, 1.9 A rated current, 28.75 A instantaneous tripping current, 1.60-2.50 A current setting range.
0.75 · 1.9 · 1.60-2.50 · 28.75
Manual motor starter, 15 kW rated power, 29 A rated current, 480 A instantaneous tripping current, 25.00-32.00 A current setting range.
15 · 29 · 25.00-32.00 · 480
Manual motor starter, 1.1 kW rated power, 2.7 A rated current, 50 A instantaneous tripping current, 2.50-4.00 A current setting range.
1.1 · 2.7 · 2.50-4.00 · 50
Manual motor starter, 2.2 kW rated power, 4.9 A rated current, 78.75 A instantaneous tripping current, 4.00-6.30 A current setting range.
2.2 · 4.9 · 4.00-6.30 · 78.75
Manual motor starter, 18.5 kW rated power, 35 A rated current, 630 A instantaneous tripping current, 30.00-42.00 A current setting range.
18.5 · 35 · 30.00-42.00 · 630
Manual motor starter, 22 kW rated power, 41 A rated current, 810 A instantaneous tripping current, 40.00-54.00 A current setting range.
22 · 41 · 40.00-54.00 · 810
Manual motor starter, 30 kW rated power, 45.5 A rated current, 975 A instantaneous tripping current, 52.00-65.00 A current setting range.
30 · 45.5 · 52.00-65.00 · 975
Legacy Soft Starter accessory, tropicalization coating
Legacy Soft Starter accessory, ability to set in Delta up to 500 V
Legacy Soft Starter accessory, tropicalization coating
Additive limiter for increasing breaking capacity to 100kA for GV2ME and GV2P
100kA
OEM List Price · Apr 2026